Series G2000 SENSOCON Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of Filter, Wind Speed, Furnace Pressure, Differential Pressure Of Pore Plate,The Pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System. Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment. There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materi
SPECIFICATION
- Ambient Temperature – -21 ~140 -6 ~60
- Rated Pressure -20 inHg~30 inHg (-68~103KPa)
- Overpressure – Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections – 1/8″ female NPT duplicate high and low pressure taps – one pair side and one pair back
- Housing – Die cast aluminum case and bezel,With acrylic cover,Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy – ±2% of full span at 70???(21??????(±3% on -0, and ±4% on -00)
- Range -20 inHg~38 inHg (-68KPa~130KPa)(Special Specification also can be ordered.)
FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERING
SENSOCON By Model Number Popularity
- FILTER BY
- Range – Pascals
Model | Description |
---|---|
G2000-100PA | Differential Pressure Gage, Range 0-100 Pa,Minor Divisions 2.0,Calibrated For Vertical Scale Position. |
G2000-125PA | Differential Pressure Gage, Range 0-125 Pa,Minor Divisions 5.0,Calibrated For Vertical Scale Position. |
G2000-250PA | Differential Pressure Gage, Range 0-250 Pa,Minor Divisions 5.0. |
G2000-300PA | Differential Pressure Gage, Range 0-300 Pa,Minor Divisions 10.0. |
G2000-30PA | Differential Pressure Gage, Range 0-30 Pa,Minor Divisions 1.0,Calibrated For Vertical Scale Position. |
G2000-500PA | Differential Pressure Gage, Range 0-500 Pa,Minor Divisions 10.0. |
G2000-60PA | Differential Pressure Gage, Range 0-60 Pa,Minor Divisions 1.0,Calibrated For Vertical Scale Position. |
G2000-750PA | Differential Pressure Gage, Range 0-750 Pa,Minor Divisions 25.0. |
Additional Information:
- SENSOCON Differential Pressure Gauge Delhi From Tirunelveli – 600107 Tamil Nadu India
- www.envirotechindustrialproduct.co.in
- www.envirotechindustrialproduct.in
- www.envirotechindustrialproducts.in