Dwyer 616KD-00-V Differential Pressure Transmitter
616KD-00-V | Dwyer Instruments | Pressure
DPT, R: 0 TO 1 IN W.C., 0-5 OR 0-10VDC FIELD SELEC
Manufacturer: Dwyer Instruments
MPN: 616KD-00-V
SKU: 616KD-00-V
Specifications
Accuracy | ±2% Full Scale |
Output Signal | 4-20 mA or unit with field selectable 0-10V or 0-5V |
Process Connection | Barbed, dual size to fit 1/8″ and 3/16″ (0.32 and 0.5 cm) ID rubber or vinyl tubing |
Power Requirements | 16 to 35 VDC (2 or 3 wire), 20 to 28 VAC (3 wire) |
Operating Pressure | 2 psi (13.8 kPa) |
Operating Temperature | 32° to 122℉ (0° to 50℃) |
Thermal Effect on Span | ±0.11% FS/℉ (±0.19% FS/℃) typical |
Thermal Effect on Zero | |
616KD-X0 | 0.6%/℉ (1%/℃) |
616KD-X1 | 0.3%/℉ (0.5%/℃) |
616KD-X2 | 0.2%/℉ (0.33%/℃) |
616KD-X3 | 0.12%/℉ (0.2%/℃) |
616KD-X4 | 0.06%/℉ (0.1%/℃) FS max. |
Zero and Span Adjustments | Push button |
Loop Resistance | DC=1000Ω max.; AC=1200Ω max |
Current Consumption | 21 mA max. |
Electrical Connections | Screw-type terminal block |
Enclosure Rating | NEMA1 (IP20) |
Media Compatibility | Air and non-combustible, compatible gases |
Mounting Orientation | Position insensitive |
Stability | ±1% FS/year |
Approvals | CE, RoHS |
Weight | 0.11 lb (0.05 kg) |
Warranty | 1 year |
Product Family Features
- One-Touch® technology for zero and span calibration
- Easy to install and maintenance
- Open screw terminals for easy wiring
- DIN mount housing
More Information & Related Documents
Family Description
The 616KD Series Differential Pressure Transmitters with One-Touch® technology are cost-effective, compact transmitters that reduce up front costs as well as expenses over the life of the product. The transmitter not only alleviates cumbersome turn pots typically found in most transmitters, but eliminate entirely the need to span the instrument during calibration. With a single digital push button, both ZERO AND SPAN are calibrated properly, nothing else is required. No additional reference pressure sources and separate calibration devices are necessary; no need to remove from service and send to a lab. All that is required of the installer or user is to let the unit sit at zero reference pressure, then push a button. That is it! The transmitter is now ready for operation. Time savings are enormous over the life of the product compared to traditional transmitters which require time to annually remove the product from service plus the additional time to actually perform a complete full-span calibration.